Small Size 80A 90A High Power AC Magnetic Contactor Electromagnetic Latching Relay

Products

Small Size 80A 90A High Power AC Magnetic Contactor Electromagnetic Latching Relay

Small Size 80A 90A High Power AC Magnetic Contactor Electromagnetic Latching Relay

Cautions of Latching Relay: 1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical

Send your inquiry

DESCRIPTION

Basic Info.
Model NO. IM901
Protective Characteristics Enclosed Rlay
Action Principle Electromagnetic Type
Size Miniature
Type Electric Parameter Relay
Contact Form 1A/1b
Color Black
Contact Material Agsno2
Rated Load 90A, 250VAC
Coil Voltage 6~48VDC
Product Name Energy Meter Parts 90A Magnetic Latching Relay
Transport Package Cartons/Pallet
Specification 38*30*16.5mm
Trademark IVY
Origin Zhejiang, China
HS Code 8536411000
Production Capacity 5, 000, 000.00/ Year
Product Description

Small Size 80A 90A High Power AC Magnetic Contactor Electromagnetic Latching Relay

Small Size 80A 90A High Power AC Magnetic Contactor Electromagnetic Latching Relay

Small Size 80A 90A High Power AC Magnetic Contactor Electromagnetic Latching Relay

Basic DataDimension(mm)38×30×16.5
Weight ( g )≈33g
Contact Arrangement1A/1B
Contact MaterialAgSnO2
Ambient Temperature-40~+70ºC
Ambient Humidity45%~90%RH
Vibration10~55Hz,1.5mm(DA)
Specification DataNominal Voltage6~48VDC
Power ConsumptionSingle Coil:1.5W, Dual Coil:3W
Max. Switching Voltage250VAC
Max. Switching Current90A
Max. Switching Power22500 VA
Contact Resistance<2.0 mΩ
Insulation Resistance1000MΩ(DC 500V)
Dielectric Creepage10mm
Dielectric StrengthAcross Open Contact>2000VAC 1min
Coil To Contact>4000VAC 1min
Electrical Life>10,000cycles
Mechanical Life>100,000cycles
Picking-up & Release Time<=20ms
Pulse Duration>=100ms
Functional Shock Resistance10G
Destructive Shock Resistance100G


Small Size 80A 90A High Power AC Magnetic Contactor Electromagnetic Latching Relay

Small Size 80A 90A High Power AC Magnetic Contactor Electromagnetic Latching Relay

Cautions of Latching Relay:
1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine, you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory. (2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5 times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status. 2.Suggestions of relay's output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after the installation. (2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is fastened and prevent relay from damages or other safety problems due to temp. Rise.. (3)The sampling signal wires of products are limited, please do not pull or torque during installation.